Benutzer-Werkzeuge

Webseiten-Werkzeuge


hardware:channels:meters:power:edl-ehz:itron_ace3000_type_260

Unterschiede

Hier werden die Unterschiede zwischen zwei Versionen angezeigt.

Link zu dieser Vergleichsansicht

Beide Seiten der vorigen RevisionVorhergehende Überarbeitung
Nächste Überarbeitung
Vorhergehende Überarbeitung
hardware:channels:meters:power:edl-ehz:itron_ace3000_type_260 [2018/01/25 15:30] – code jauhardware:channels:meters:power:edl-ehz:itron_ace3000_type_260 [2023/06/21 07:51] (aktuell) justinotherguy
Zeile 26: Zeile 26:
 { {
   "retry": 0,   "retry": 0,
-  "daemon": true, 
   "verbosity": 15,   "verbosity": 15,
-  "log": "/var/log/vzlogger.log",+  "log": "/var/log/vzlogger/vzlogger.log",
      
 "local": { "local": {
     "enabled": false,     "enabled": false,
-    "port": 8080,+    "port": 8081,
     "index": true,     "index": true,
     "timeout": 0,     "timeout": 0,
Zeile 81: Zeile 80:
 { {
     "retry": 0,            // how long to sleep between failed requests, in seconds     "retry": 0,            // how long to sleep between failed requests, in seconds
-    "daemon": true,        // run periodically 
     "verbosity": 15,         // between 0 and 15     "verbosity": 15,         // between 0 and 15
-    "log": "/var/log/vzlogger.log",     // path to logfile, optional+    "log": "/var/log/vzlogger/vzlogger.log",     // path to logfile, optional
  
     "local": {     "local": {
         "enabled": false,   // should we start the local HTTPd for serving live readings?         "enabled": false,   // should we start the local HTTPd for serving live readings?
-        "port": 8080,       // the TCP port for the local HTTPd+        "port": 8081,       // the TCP port for the local HTTPd
         "index": true,      // should we provide a index listing of available channels if no UUID was requested?         "index": true,      // should we provide a index listing of available channels if no UUID was requested?
         "timeout": 30,      // timeout for long polling comet requests, 0 disables comet, in seconds         "timeout": 30,      // timeout for long polling comet requests, 0 disables comet, in seconds
Zeile 97: Zeile 95:
  {  {
             "enabled": true,               // disabled meters will be ignored             "enabled": true,               // disabled meters will be ignored
-            "skip": false,                  // if enabled, errors when opening meter will lead to meter being ignored+            "allowskip": false,                  // if enabled, errors when opening meter will lead to meter being ignored
             "protocol": "s0",             "protocol": "s0",
             "aggtime": -1,             "aggtime": -1,
hardware/channels/meters/power/edl-ehz/itron_ace3000_type_260.1516890608.txt.gz · Zuletzt geändert: 2018/01/25 15:30 von jau